Hydronic System, Controls & Accessories
Aquastats
Aquastats - single function
Filter
Application
High or Low Limit Control
Circulator
High Limit Control
High Limit, Manual Reset
High and Low limit
Circulator Control and High Limit or Low Limit
Oil Aquastat Controller
Aquastat Relay with High Limit Protection, Low Limit and Circulation Control
Triple Aquastat Relay with High Limit Protection
Triple Aquastat Relay with High Limit Protection, Low Limit and Circulation Control
Aquastat Relay with High Limit Control
Line Voltage Circulator Control and Low Voltage Power Supply and Limit Control, May be used with Series 60 Low Limit Control
Combination Aquastat Relay for use with either Low Voltage or Power Pile Gas Valves
Circulator Control and Low Limit
High Limit; Manual Reset
Immersion type controllers for regulating and limiting the tank temperature in water heaters|High Limit
Line Voltage Circulator Control and Low Voltage Power Supply and Limit Control|May be used with Series 60 Low Limit Control
High Limit and Circulator
High Limit Protection, Low Limit and Circulation Control
Bulb Size (in)
3/8 in.
3/8 in x 2 7/8 in
3/8 in. x 2 7/8 in.
Burner Control Circuit
Burner 1.25 A at 24 V AC|Burner 30 VA (Total Load) Terminals B1-B2 and TV-Z
Burner 0.8 A Maximum at 24 V AC
Burner Control Circuit @ 24V (A)
Burner 1.25 A at 24 V AC|Burner 30 VA (Total Load) Terminals B1-B2 and TV-Z
Burner 0.8 A Maximum at 24 V AC
Depth (In.)
2 in.
2 in
2 3/4 in
4.25 in
4.38 in.
6.13 in.
4.31 in
5.25 in
5.25 in.
2.12 in.
3.12 in.
3 7/16 in
2 1/8 in.
2 3/4 in.
3 1/16 in.
Differential
5 Degree F Fixed to 3 Degree C Fixed
5 Degree F to 30 Degree F Adjustable to 3 Degree C to 17 Degree C Adjustable
Manual Reset
5 Degree F to 30 Degree F
8 Degree F Fixed
15 Degree F Fixed
10 Degree F
10 Degree F to 25 Degree F
Full Load Amps @ 120VAC
8 A
8 A
7.4 A
7.4 A
4.4 A
4.4 A
1.2 A
Full Load Amps @ 240VAC
5.1 A
5.1 A
3.7 A
3.7 A
3.7 A
4.4A
1.4 A
Height (In.)
5.63 in.
5.63 in
3.88 in.
5 5/8 in
7.13 in
6.13 in.
4.38 in.
4.31 in.
6.13 in
7.13 in.
5.62 in.
6.12 in.
7 1/8 in
5 5/8 in.
3 7/8 in.
6 1/8 in.
Humidity Range (% RH)
0 to 95% RH
0 to 95
Includes
1/2 in. Well 123869A
1/2 in. well - 123869A
Stop factory-set at 240 F (116 C)|Heat Conductive Compound
Heat Conductive Compound
1/2 in. well - 123869A; Stop factory-set at 240 F (116 C)
1/2 in Well - 123869A
Heat Conductive Compound|Stop factory-set at 250 F (121 C)|Well adapter
Bracket for strap-on mounting, Heat Conductive Compound, Stop factory-set at 240 F (116 C)
5 1/2 ft (1.7 m) Capillary
5 1/2 ft Capillary|1.7 m Capillary
5 1/2 ft (1.7 m) Capillary|Stop factory-set at 250 F (121 C)|Heat Conductive Compound
Stop factory-set at 240 F (116 C), Heat Conductive Compound
Stop factory-set at 200 Degree F (93 C)
No Well
Molex® plug for use with vent damper, Heat Conductive Compound
50 VA transformer, Heat Conductive Compound
Auxiliary ZC and ZR terminals may be used to provide circulator zone control through an R845A Switching Relay, Heat Conductive Compound, Horizontal case
Auxiliary ZC and ZR terminals may be used to provide circulator zone control through an R845A Switching Relay|Heat Conductive Compound to Horizontal case
50 VA transformer|Heat Conductive Compound
Auxiliary ZC and ZR terminals may be used to provide circulator zone control through an R845A Switching Relay. Heat-conductive compound and vertical case.
Insulation Depth (In.)
1.5 in.
3 in.
1.5 in to 3 in
Locked Rotor Amps @ 120V
48 A
44.4 A
26.4 A
26.4 A
8 A
1.2 A
Locked Rotor Amps @ 240V
30.6 A
30.6 A
22.2 A
22.2 A
22.7 A
26.4 A
48 A
3.7 A
Millvolt
0.25 A @ 0.25 to 12 V DC
0.25 A at 1/4 to 12 V DC
Mounting
Horizontal or Vertical
Horizontal Mount
Horizontal
Horizontal or Vertical or Surface Mounting
Flush Mounted, Remote Mount, Well Mount, Horizontal Mount, Vertical Mount
Vertical Mount
Horizontal Mount, Vertical Mount
Exposed Junction Box
Horizontal/Vertical
Requires
R845A Switching Relay|Requires C554A Cadmium Sulfide Flame Detector (ordered separately)|24V, 2-wire Thermostat such as the T87F|125026AAJ|4074BRR Dial Stop Replacement
System Switching
Contacts break on temperature rise
High Limit Switch breaks on temperature rise|Low Limit Switch breaks on temperature rise
High Limit Switch breaks on temperature rise|Circulator Switch makes on temperature rise
SPDT Switching
SPST
SPDT
Temp. Range
240 Degree F to 116 Degree C to 100 Degree F to 38 Degree C
241 Degree F to 116 Degree C to 100 Degree F to 38 Degree C
242 Degree F to 116 Degree C to 100 Degree F to 38 Degree C
270 Degree F to 132 Degree C to 130 Degree F to 54 Degree C
100 Degree F to 240 Degree F
65 Degree F to 200 Degree F
180 Degree F to 240 Degree F
120 Degree to 240 Degree F
130 Degree F to 240 Degree F
100 Degree F to 200 Degree F
100 Degree F to 180 Degree F
150 Degree F
Type
SPST
Manual Controller
High Or Low Limit Mount Controller
Electronic Oil Aquastat
Aquastat Relay
Hydronic Heating Control
Width (In.)
2.13 in.
2 in.
2.13 in
4.13 in.
2 in
2.63 in
3.06 in.
4.38 in.
3.13 in
3.44 in
3.44 in.
4.31 in.
5 1/4 in
4 1/8 in.
4 3/8 in.
Apply Filter
Show:
12
24
36
48
96
Sort By:
Brand A-Z
Brand Z-A
Resideo
Zoom
View
Aquastat - Single Function
High or Low Limit Horizontal Mount Controller with SPDT, Operating Range 100-240 Degree F, 3 inch Capillary
Mfr #L6006A1145/U
Part #L6006A1145
Availability:
call for price
Add to cart
Resideo
Zoom
View
Aquastat - Single Function
High or Low Limit Surface Mount Controller with SPDT, Operating Range 65-200 Degree F, Factory Stop at 200 Degree F
Mfr #L6006C1018/U
Part #L6006C1018
Availability:
call for price
Add to cart
Items
1
to
9
of 2 total
(856)663-7640
$
...
Availability:
Add to cart
More details
×
User Login
User Name
Password
Show Password
Forgot Password?
Register user /
×
Reset Password
Your Registered Email
×
Forgot Password
E-Mail
×
User Registration
First Name
*
Last Name
Customer Number
*
E-Mail(Username)
*
Zip Code
*
×
Please wait...
Please do not press Back or Refresh payment is processing...
×
×
Save to job list...
my job list